This page explains how to configure and customize the Energy-Exergy Analysis Engine for your specific needs.
System Parameters¶
Reference Temperature¶
The reference temperature (T0) is crucial for exergy calculations. It represents the dead state temperature:
system.T0 = 10 # Reference temperature in °C
Note
The reference temperature should represent the ambient conditions. Typical values are 0°C, 10°C, or 25°C.
Default Values¶
Each system class comes with sensible default values for physical properties:
Water density: 1000 kg/m³
Water specific heat: 4186 J/(kg·K)
Air density: 1.2 kg/m³
Insulation thermal conductivity: 0.03 W/(m·K)
You can override these defaults by setting the attributes directly:
EB = enex.ElectricBoiler()
EB.k_ins = 0.04 # Custom insulation conductivity
EB.rho_w = 995 # Custom water density
Advanced Configuration¶
For more complex scenarios, you can:
Modify subsystem parameters
Adjust calculation tolerances iterative solvers
Customize output formats